MAL-MET Engineering Selection Tool

Fiber Optic Cable Jetting Machine & Compressor Configurator

Select your cable and duct parameters. The engineering engine automatically computes the duct inner bore (ID), validates the minimum aerodynamic annular clearance (≥ 1.0 mm per side), and presents compatible MAH-4 series all-roller direct-drive blowing machines along with matching ATMOS mobile screw compressors.

Equipment Selection Filters
1 What is being installed?
Custom value: mm
2 What conduit / duct is being used?
Custom value: mm
Custom value: mm
3 Required blowing distance?
Custom value: km
4 Machine Operating Version:
5 Additional Options:
Engineering Geometry Indicator
Duct Outer Diameter (Dz): 14.0 mm
Duct Wall Thickness (s): 2.0 mm
Duct Inner Bore (Dw = Dz - 2s): 10.0 mm
Cable Outer Diameter (dk): 7.0 mm
Radial Annular Clearance per side ((Dw - dk) / 2): 1.50 mm
Maximum Allowed Cable OD (Dw - 2.0 mm): 8.0 mm
Diameter Fill Ratio: 70.0%
Required Route Length: All (no limit)
Duct OD (Dz)
Duct ID (Dw)
Cable (dk)
Cross-section generated proportionally in real time.

1. Matching MAL-MET Cable Jetting Machines

Version: Electronic (Automated)

2. Recommended ATMOS Screw Compressors

Matched by conduit caliber and airflow demand

Configured Set Summary

The selected set satisfies strict aerodynamic annular clearance standards (≥ 1.0 mm per side) and guarantees reliable cable jetting with complete crush and buckle protection.

Technical Consultation: +48 602 153 516

Engineering Knowledge Base: Cable Jetting Principles & Parameters

1. Why is the minimum annular clearance 1.0 mm per side (2.0 mm on diameter)?

In pneumatic cable jetting, pressurized airflow must freely pass around the cable boundary layer to generate an air cushion that floats the cable off the bottom of the conduit and creates forward pulling shear stress. Reducing clearance below 1.0 mm per side (2.0 mm on diameter) dramatically increases aerodynamic friction, causes mechanical drag, and prevents reaching installation distances beyond a few hundred meters.

2. The critical impact of duct wall thickness (SDR) on internal bore (ID)

Conduits with the exact same outer diameter can have vastly different internal bores. For instance, a thin-walled ⌀ 10×1.0 mm microduct has an internal diameter of 8.0 mm (accommodating cables up to 6.0 mm), whereas a heavy-duty thick-walled ⌀ 10×2.0 mm microduct has an internal diameter of only 6.0 mm (limiting cable size to max 4.0 mm). The MAL-MET configurator enables entering exact wall thicknesses down to tenths of a millimeter to prevent costly installation failures.

3. Why an integrated aftercooler and water separator is essential

Rotary screw compressors generate air at high discharge temperatures (70–90°C). Hot air pumped into an HDPE subduct heats and softens the conduit wall and cable jacket, drastically increasing friction coefficients. Compressors offered by MAL-MET are equipped with an integrated aftercooler and cyclonic moisture separator standard, cooling and dehumidifying the air stream before injection into the blowing head.